T SERIES

Three-phase electric motor 2 poles, 4 poles, 6 poles, 8 poles and 12 poles.

GENERAL FEATURES

kWfrom 0,09 kW to 11 kW
HORSEPOWER Hpfrom 0,12 Hp to 15 Hp
POLES NR.2, 4, 6, 8 poles
rpm 2800, 1400, 900, 700 rpm
FRAME SIZEfrom MEC 56 to MEC 132M

ELECTRIC AND TECHNICAL FEATURES

Class F insulation – IP55 protection – Voltage test V400-50Hz

2 POLES

TYPE
kW
Hp
rpm
(In) ARend. % IE2 - IE3Cos. φ Ia/In(Cn) NmCa/CnCmax/CnWeight Kg
T 56 A20,150,2027500,558,5IE20,743,60,522,32,53,5
T 63 A20,180,2527900,5860,4IE20,734,20,623,13,34,5
T 63 B20,250,3527800,7764,8IE20,7240,862,72,94,7
T 63 C2*0,370,527701,166,5- - -0,733,71,282,22,54,9
T 71 A20,370,52830169,5IE20,7551,253,23,86,2
T 71 B20,550,7528001,474,1IE20,764,61,882,636,8
T 71 C2*0,75128301,877,4IE20,775,12,532,83,18
T 80 A20,75128601,880,7IE30,756,32,503,13,59,7
T 80 B21,11,528202,482,7IE30,815,83,732,72,910,3
T 80 C2*1,5227803,281,3IE20,866,25,152,9311
T 80 D2*1,752,428003,780,3- - -0,855,85,972,72,911,5
T 90S A21,5228803,184,2IE30,836,94,9733,213,5
T 90S B2*2,2328504,681,4- - -0,856,27,372,62,814
T 90L A22,2328604,485,9IE30,846,57,352,93,115,2
T 90L B2*342850683- - -0,875,710,052,62,916
T 100 A2342860687,1IE30,83710,022,83,121,7
T 100 B2*45,52850883,9- - -0,866,213,402,52,722,3
T 112 A245,528707,688,1IE30,867,313,312,73,129,6
T 112 B2*5,57,5286010,387IE20,896,418,372,32,630,3
T 112 C2*7,510287014,386,3- - -0,886,624,962,32,733
T 132S A25,57,5290010,389,2IE30,867,518,112,73,140
T 132S B27,510288013,890,1IE30,876,824,872,6346,5
T 132M A29,212,5291016,490,8IE30,897,830,192,52,956
T 132M B2*1115289019,389,4IE20,927,136,352,22,557,2

* = Power not unified – l = Current – a = Start-up – n = Nominal – C = Torque

All technical data can be modified and updated. DAMIEN Electric Motors will can modify them without any notification.

4 POLES

TYPE
kW
Hp
rpm
(In) AEff. % IE2 - IE3Cos. φ Ia/In
(Cn) Nm Ca/Cn
Cmax/Cn
Weight Kg
T 56 A40,090,1213600,4156,6- - -0,562,70,632,42,63,3
T 63 A40,130,1813800,5262,5IE20,582,90,902,62,83,8
T 63 B40,180,2513700,6564,7IE20,612,81,252,42,44
T 63 C4*0,250,3513800,8764,8- - -0,6431,732,225
T 71 A40,250,3514100,868,5IE20,664,21,692,52,86,3
T 71 B40,370,514001,172,7IE20,673,82,522,32,56,7
T 71 C4*0,550,7513901,677,1IE20,644,33,782,42,67,9
T 80 A40,550,7514001,677,1IE20,634,43,752,52,89
T 80 B40,75114201,882,5IE30,734,75,042,73,110,7
T 80 C4*1,11,514102,976- - -0,723,67,451,82,211
T 90S A41,11,514202,684,1IE30,734,67,402,52,613,2
T 90S B4*1,5214103,978,2- - -0,713,810,162,12,213,7
T 90L A41,5214303,585,3IE30,735,310,022,7316,4
T 90L B41,82,514204,383,7IE20,724,712,112,32,516,7
T 90L C4*2,2314105,479,5- - -0,743,814,901,92,117
T 100 A42,2314304,786,7IE30,78514,692,52,721
T 100 B43414406,487,7IE30,775,419,902,52,623,1
T 100 C4*45,514308,783,0- - -0,804,426,7122,123,5
T 112 A445,51440888,6IE30,816,326,532,62,931,8
T 112 B4*5,57,5143011,584,2- - -0,824,836,7322,332,5
T 132S A45,57,5145010,889,6IE30,825,436,222,62,749,5
T 132M A47,510145014,290,4IE30,84649,402,9358
T 132M B4*9,212,5144017,589,3IE20,854,961,012,42,559,2
T 132M C4*1115143021,887,8- - -0,834,273,462,12,260

* = Potenza non unificata   –   l = Corrente   –   a = Avviamento   –   n = Nominale   –  C = Coppia

All technical data can be modified and updated. DAMIEN Electric Motors will can modify them without any notification.

6 POLES

TYPEkWHprpm(In) AEff. %IE2 - IE3Cos. φIa/In(Cn) NmCa/CnCmax/CnWeight Kg
T 63 A60,110,158800,5747,5- - -0,592,31,191,81,94,8
T 71 A60,180,259000,6956,6IE20,652,91,912,42,37,5
T 71 B60,250,358900,961,6IE20,642,42,681,927,8
T 80 A60,370,59301,267,6IE20,653,43,802,62,710,7
T 80 B60,550,759101,673,1IE20,673,15,772,32,511
T 90S A60,751930278,9IE30,683,57,702,32,713,1
T 90S B6*1,11,59103,177,3- - -0,662,711,541,82,213,6
T 90L A61,11,59302,981IE30,673,611,302,12,816
T 90L B6*1,41,99203,877,4- - -0,692,914,531,72,116,5
T 100 A61,529403,882,5IE30,703,715,242,42,922,7
T 100 B6*1,82,59204,778,7- - -0,703,218,682,12,323,2
T 112 A62,239505,384,3IE30,714,522,122,2331,2
T 112 B6*2,83,89306,781,2- - -0,743,828,751,62,232
T 132S A6349506,985,6IE30,744,730,161,82,845
T 132M A645,59508,986,8IE30,754,640,212,12,850
T 132M B65,57,596011,888IE30,764,854,711,82,956,8

* = Power not unified – l = Current – a = Start-up – n = Nominal – C = Torque

All technical data can be modified and updated. DAMIEN Electric Motors will can modify them without any notification.

8 POLES

TYPEkWHprpm(In) AEff. %IE2 - IE3Cos. φIa/In(Cn) NmCa/CnCmax/CnWeight Kg
T 71 A80,150,206500,851- - -0,532,22,202,22,47
T 80 A80,250,356701,254- - -0,562,43,562,32,510,5
T 90S A80,370,56901,562- - -0,5835,122,52,611,5
T 90S B8*0,550,756902,359- - -0,592,17,611,8212
T 90L A80,550,756902,362- - -0,572,97,612,22,415
T 90L B8*0,660,96802,760- - -0,602,69,271,92,115,8
T 100 A80,7517002,670- - -0,603,710,232,32,420,8
T100 B81,11,56903,769- - -0,622,715,221,71,921,8
T 112 A81,527004,576- - -0,643,820,462,12,332
T 132S A82,23710678- - -0,69429,591,92,144
T 132M A8347007,979- - -0,704,240,9322,252

* = Power not unified – l = Current – a = Start-up – n = Nominal – C = Torque

All technical data can be modified and updated. DAMIEN Electric Motors will can modify them without any notification.

DOWNLOAD AREA

INFORMATION REQUEST – ELECTRIC MOTOR T SERIES

1 + 7 = ?